WEBVTT

00:00:00.000 --> 00:00:01.792 align:left
DRAPING THE PATIENT

00:00:22.337 --> 00:00:25.698
The smooth side downwards.

00:00:26.895 --> 00:00:33.137
Ask the patient to lift their head and back, and place it under the patient.

00:00:40.291 --> 00:00:43.462
We will now make a triangular fold.

00:00:45.420 --> 00:00:48.611
Ask the patient to lift their head a bit and place it under the head.

00:00:59.106 --> 00:01:03.106
This one is rectangular and should be placed over the patient.

00:01:10.020 --> 00:01:13.449
And swing the table above the patient.

00:01:20.583 --> 00:01:22.940
This is to cover the operating lamp.

00:01:31.979 --> 00:01:35.170
We will now use towel clamps.

00:01:40.040 --> 00:01:47.446
Place the drape with the triangular fold so that it crosses the patient's eyes.

00:01:49.661 --> 00:01:50.637
And attach.

00:02:00.223 --> 00:02:05.901
The drape over the patient's chest should not be attached to underlying drape,

00:02:05.941 --> 00:02:10.075
so that the patient is not hindered if they get up or move during surgery.

00:02:10.806 --> 00:02:14.806
Therefore, we will attach the overlying drape to the one on the head.

00:02:16.375 --> 00:02:20.375
Careful so you don't pinch the patient's skin.

00:02:29.472 --> 00:02:31.694
We move on to the suction.

00:02:50.115 --> 00:02:54.668
Place the tube over the patient's chest and make a small tunnel.

00:02:55.874 --> 00:02:59.874
Use the towel clamp to fasten the roof.

00:03:05.210 --> 00:03:09.167
Now the tube can be moved freely, and the length can be adjusted.

00:03:09.207 --> 00:03:15.691
Alternatively, the tube can be locked in place by pulling it through the towel clamp.

00:03:16.694 --> 00:03:19.621
The tube will now stay in place.

00:03:20.732 --> 00:03:31.951
This is a handpiece sleeve and I'm putting the tape aside.

00:03:33.090 --> 00:03:38.902
The protective plastic sleeve has a single layer on one side and a double layer on the other, which I will open.

00:03:42.053 --> 00:03:46.206
Take the handpiece and connect it to the other end.

00:03:47.541 --> 00:03:49.885
Press it on without twisting.

00:04:04.140 --> 00:04:10.495
Pull the plastic back slightly, but not too far, so that the unsterile part is not exposed.

00:04:10.894 --> 00:04:14.939
Wrap the plastic around and tape it up.

00:04:16.098 --> 00:04:26.782
Put some of the tape both on the handpiece's metal and on the plastic so it doesn't slide down where it's not sterile.

00:04:37.279 --> 00:04:39.994
This bowl contains saline solution.

00:04:40.034 --> 00:04:44.034
It's used for surgical wound irrigation.

00:04:57.290 --> 00:05:01.290
I'm now assembling the local anesthetic syringe.

00:05:12.046 --> 00:05:16.200
The nurse will then provide the needed anesthetic.
